Reference 303 is trapped metallic oxide, and on most joints where it appears the material is
aluminium: its surface oxide is tenacious enough that ordinary arc heat does not remove it,
and a fragment ends up frozen into the weld if it is not stripped or broken up first. Steel
produces the same imperfection far less often, because its native oxide film is thinner and
breaks up more readily under the arc.
The cause matrix is a cleaning-and-coverage story: film not removed before welding,
shielding lost mid-pass so the pool re-oxidises while still molten, or a cleaning action too
weak for the alloy on the wrong polarity.
The one usable in-process signal is specific to GTAW on aluminium: the cathodic cleaning
band ahead of the arc, visible on a pool camera, where a band too narrow for the joint is
the precursor to film later confirmed on radiography — the standard route, since a thin film
gives usable but marginal contrast.
Reference 303 sits beside reference 301, slag inclusion, and
reference 302, flux inclusion, and next to reference 3042,
copper inclusion, the metallic one.
The column that matters most is the last one. An inspection family marked as not finding
this imperfection will not find it however carefully it is applied, and planning around
that is cheaper than discovering it during a final examination.
Therness pages never reproduce a standard's acceptance values: those tables are
copyrighted and belong in the copy you hold. What follows is the pointer — which document
governs, and which part of it to open.