Reference 4021 narrows reference 402, lack of penetration, to one configuration: a
single-side butt weld, welded from one side only. A double-sided joint can
sometimes be corrected at the root by back-gouging and re-welding from the other side; the
joint 4021 describes never has that option — the root pass is the only pass that reaches it.
The cause matrix is the same physical story as 402 — arc energy, fit-up and process — but
every cause weighs more here: a root gap or backing mismatch forgivable on a joint with a
corrective back pass is unforgivable on this one.
Detection depends on the section: back-side VT confirms root condition afterward on plate
and other open sections, but not on pipe girth welds and closed sections, where face-side
thermal and camera evidence during the pass, plus radiography after, carry the weight.
See reference 402, lack of penetration, the parent
designation; reference 4013, lack of root fusion, the
bonding failure most confused with a penetration shortfall at the same location; and
reference 401, lack of fusion, in general.
The column that matters most is the last one. An inspection family marked as not finding
this imperfection will not find it however carefully it is applied, and planning around
that is cheaper than discovering it during a final examination.
Therness pages never reproduce a standard's acceptance values: those tables are
copyrighted and belong in the copy you hold. What follows is the pointer — which document
governs, and which part of it to open.