Welding glossary
Acceptance criteria (welds)
Acceptance criteria for a weld are the combined rule set that decides pass or fail: which quality level of imperfection applies, which acceptance level a specific inspection method invokes, and what extent of inspection is required before the two can be checked at all.
A specification that says a weld must meet “acceptance criteria” is naming a bundle, not one rule, and the three parts of that bundle answer different questions. Confusing them is not a technicality — a weld can satisfy two of the three and still fail a review, because nobody checked the third.
Quality level is the band of allowed imperfections published by a standard — ISO 5817 levels B, C and D are the reference case. It answers “how much of a given imperfection type is this joint allowed to have.” A quality level on its own says nothing about which inspection method was used to check it.
Acceptance level is narrower and method-specific: some inspection-method standards define their own acceptance-level scheme, keyed to a particular test result rather than to the joint as a whole. The radiographic testing family is the clearest example — it publishes acceptance levels tied to specific radiographic indications, correlated with but not identical to a general quality level, because a radiograph and a visual inspection cannot always see the same flaw the same way. A drawing that calls out “acceptance level 2” without naming which method’s scheme it means is not fully specified.
Inspection level (also called examination or testing extent) is a separate axis again: which method or methods apply, and how much of the weld — by length, by joint, or by a sampling plan — actually gets examined. ISO 17635 sets the general rules for choosing non-destructive testing methods and extent for welds, above the level of any single method standard.
The decision rule that follows: read the three together, never substitute one for another. A tight quality level paired with a thin inspection extent does not raise confidence that the WPS was met — it only limits how much of the joint was actually checked against it. A drawing that specifies ISO 5817 level B and a single acceptance level, but leaves the inspection extent at “spot check,” has not raised the bar on the weld: it has only narrowed how much of the joint that bar was ever measured against, and the length or number of joints outside the sampled extent carries no record either way.
Where you meet this term
- Contract and design specifications, as the single line a fabricator is actually held to
- Inspection procedures, where the acceptance level tells an NDT technician which finding size is reportable
- Welding procedure specifications, where the quality level and the required inspection extent are both stated
- Audit and dispute situations, where the three terms get conflated and a record has to show which one was actually met