# Cold lap (thermal signature)

Source: https://www.therness.com/glossary/cold-lap-thermal-signature/
Language: en

Welding glossary

In this glossary, a cold-lap thermal signature means a repeatable spatial or time-based anomaly in thermal weld data that flags conditions associated with poor fusion at a weld toe. It is a process-monitoring indication, not proof that a cold-lap imperfection exists.

Cold lap is a physical fusion problem near a weld toe. Research describing the imperfection calls it a small incomplete-fusion interface at or near that toe; the [original experimental characterisation](https://research.chalmers.se/en/publication/124625) used microscopy to examine the interface. This glossary uses **cold-lap thermal signature** for a different thing: the pattern a monitoring system associates with the process conditions or surface response around such events. Recent [multimodal welding research](https://arxiv.org/abs/2609.07893) likewise treats cold lap as a labelled defect class inferred from process data, not as a thermal pixel value that proves the physical interface exists.

This page does not assign the signature a universal shape or unit. It might be expressed through a local [thermal gradient](https://www.therness.com/glossary/thermal-gradient/), the width of the heated band, a cooling curve, or a combination of features. Camera band, angle, [emissivity](https://www.therness.com/glossary/emissivity/), joint geometry, process and material all change the recorded field. For that reason, the signal must be established against labelled reference welds made under the relevant setup. A generic “cold” pixel threshold is not a defensible definition.

## Worked distinction: signature and imperfection

Imagine a fillet-weld monitoring rule built from a documented reference set. On one production run it flags a narrow, persistent anomaly along the lower toe while the [weld pool](https://www.therness.com/glossary/weld-pool/) passes. That flag is the **cold-lap thermal signature**. It identifies a location and time that deserve review.

If a qualified follow-up examination or section then reveals an unfused toe interface, the physical finding is **cold lap**, related to [lack of fusion](https://www.therness.com/defects/401-lack-of-fusion/) or [overlap](https://www.therness.com/defects/506-overlap/) according to the observed geometry and the classification document used by the job. If follow-up finds sound fusion, the thermal flag remains a real process anomaly but is not a cold-lap defect. The signal and the imperfection therefore cannot share one pass/fail label.

This term is useful in welding data review because it keeps monitoring evidence at the correct level. [Thermography](https://www.therness.com/glossary/thermography/) can locate and trend an unusual surface response; the specified inspection and acceptance documents decide whether the joint contains a reportable imperfection and what happens next.

## Where you meet this term

- Thermal weld-monitoring rules trained against labelled sound and cold-lap reference welds
- Run-to-run maps of toe temperature, heated-band width and cooling behaviour
- Process anomaly records used to select a weld for confirmatory inspection
- Root-cause reviews that align thermal data with a macrosection or another qualified examination

## Related terms

[Thermography](https://www.therness.com/glossary/thermography/)

Thermography is the use of infrared imaging to record and display the surface temperature distribution of an object as a two-dimensional thermal image, rather than a single-point temperature reading.

[Thermal gradient](https://www.therness.com/glossary/thermal-gradient/)

A thermal gradient is the rate of change of temperature with distance across or along a workpiece, and it is the quantity that drives heat flow, thermal stress and distortion during and after welding.

[Lack of fusion](https://www.therness.com/glossary/lack-of-fusion/)

Lack of fusion is the absence of a fusion bond between weld metal and either the parent material or an adjacent weld pass, where the surfaces met without reaching fusion temperature.

[Weld pool](https://www.therness.com/glossary/weld-pool/)

The weld pool is the localized volume of molten metal created by the welding heat source, into which filler metal is added and from which the weld bead forms as it solidifies.

[Emissivity](https://www.therness.com/glossary/emissivity/)

Emissivity is the ratio between the thermal radiation emitted by a real surface and that emitted by an ideal blackbody at the same temperature, expressed as a dimensionless value between zero and one.

## Imperfections this term relates to

- [Incomplete fusion (ref. 401)](https://www.therness.com/defects/401-lack-of-fusion/)Lack of fusion and penetration — ISO 6520-1 group 4.
- [Overlap (ref. 506)](https://www.therness.com/defects/506-overlap/)Imperfect shape and dimension — ISO 6520-1 group 5.

[All glossary terms](https://www.therness.com/glossary/)