Detecting a defect and sizing it are different jobs, and a method that excels at one can be
mediocre at the other. Length — the extent of an indication measured along the weld — and
height, meaning its through-wall or depth extent, are two different numbers, and a quality-level
comparison, an ISO 6520-1 classification and a fitness-for-service
calculation each depend on them to different degrees: length alone is often enough to classify
an imperfection type, but height is what a fracture-mechanics assessment of a planar flaw
actually needs.
Radiographic and direct visual methods read length reliably, because both project the joint onto
a flat image or a direct view and a linear extent in that plane is a straightforward measurement.
Height is the dimension they struggle with: film density and geometric assumptions stand in for
a direct through-wall reading, and the result degrades for a flaw that is not favorably oriented
to the beam — the reason a planar defect like lack of fusion is
harder to size by radiography than a rounded one like gas pore.
Ultrasonic techniques split on the same axis, but not as one method. Phased-array (ISO 13588)
and time-of-flight diffraction (ISO 10863) size through-wall height from diffracted sound
travel time at the flaw tip — a physical measurement rather than an inference. Conventional
pulse-echo UT under ISO 17640 sizes height a different way, by
amplitude drop against a reference reflector, and that inference carries materially wider
uncertainty than a diffraction-based reading. All three still build length the same way, by
scanning and stitching multiple probe positions, which is comparatively coarser than their
height reading. Surface methods — magnetic particle and liquid penetrant testing — size length
at the surface only and give no through-wall information at all, because neither can see below
the surface it is applied to.
Choosing an NDT method for a joint is therefore partly a sizing decision, not only a detection
one: the acceptance criterion that actually governs the joint decides which dimension has to be
trusted, and that decides which method belongs on the joint.