Focal law
A focal law is the calibrated set of per-element time delays applied to a phased array probe so the pulses from every element combine into one ultrasonic beam steered to a chosen angle and focused at a chosen depth in the part.
- Formula
- Δtₙ = [F − √(F² + xₙ² − 2·F·xₙ·sin θ)] / V, for element position xₙ, focal distance F, steering angle θ and sound velocity V in the wedge or test material; the delays are referenced to the element with the longest path so every Δtₙ stays non-negative, and setting F to infinity reduces the same law to plain angular steering with no focusing; single-medium form — a wedge adds a Snell refraction step at the interface
A focal law is not the beam itself; it is the instruction that produces it. A phased array probe fires many small elements together, and a focal law is the calibrated set of time delays — one per element — that makes their individual wavefronts combine, by interference, into a single beam pointed where the operator wants it. Change the delay set and the same probe produces a different beam without moving the probe or the part.
Three things a focal law fixes at once, and changing one without recalculating the others produces the wrong law for the sequence: the active aperture — which elements in the array fire for this law, the angle the resulting beam takes as it refracts into the test material, and the focus depth — the distance along that beam path where the wavefronts arrive in phase and the beam is narrowest. A sequence built for one inspection is usually dozens of these laws, each covering one angle or one depth, stored and fired in order so the display assembles them into a single sectorial or linear image.
The delay itself follows directly from geometry: within one medium, a wave travelling from element position xₙ to a focal point at distance F and angle θ covers a path length that depends on xₙ, and converting that path difference to a time delay, using the sound velocity V in that medium, is what the formula above computes. Getting V wrong — the single most common calibration error — shifts every focus depth in the sequence together, so a probe, wedge and material velocity check belongs ahead of any sizing decision on a lack-of-fusion indication, not after one.
Where you meet this term
- PAUT technique sheets and procedures, where each focal law in a scan sequence is listed with its angle and focus depth
- Instrument calibration and wedge delay verification, confirming a programmed delay set actually produces the intended beam
- Sizing and characterisation of a planar indication, where focus depth is chosen to place the beam waist at the reflector
- Probe and wedge qualification records, since a delay set is specific to one probe-wedge-material combination