# Focal law

Source: https://www.therness.com/glossary/focal-law-paut/
Language: en

Welding glossary

A focal law is the calibrated set of per-element time delays applied to a phased array probe so the pulses from every element combine into one ultrasonic beam steered to a chosen angle and focused at a chosen depth in the part.

Formula

Δtₙ = \[F − √(F² + xₙ² − 2·F·xₙ·sin θ)\] / V, for element position xₙ, focal distance F, steering angle θ and sound velocity V in the wedge or test material; the delays are referenced to the element with the longest path so every Δtₙ stays non-negative, and setting F to infinity reduces the same law to plain angular steering with no focusing; single-medium form — a wedge adds a Snell refraction step at the interface

Full guide

[Focal law: the long-form guide](https://www.therness.com/blog/phased-array-ultrasonic-testing-paut-weld-inspection-guide/)

This page defines the term. The guide works through how it is calculated, controlled and evidenced.

A focal law is not the beam itself; it is the instruction that produces it. A phased array probe fires many small elements together, and a focal law is the calibrated set of time delays — one per element — that makes their individual wavefronts combine, by interference, into a single beam pointed where the operator wants it. Change the delay set and the same probe produces a different beam without moving the probe or the part.

Three things a focal law fixes at once, and changing one without recalculating the others produces the wrong law for the sequence: the **active aperture** — which elements in the array fire for this law, the **angle** the resulting beam takes as it refracts into the test material, and the **focus depth** — the distance along that beam path where the wavefronts arrive in phase and the beam is narrowest. A sequence built for one inspection is usually dozens of these laws, each covering one angle or one depth, stored and fired in order so the display assembles them into a single sectorial or linear image.

The delay itself follows directly from geometry: within one medium, a wave travelling from element position xₙ to a focal point at distance F and angle θ covers a path length that depends on xₙ, and converting that path difference to a time delay, using the sound velocity V in that medium, is what the formula above computes. Getting V wrong — the single most common calibration error — shifts every focus depth in the sequence together, so a probe, wedge and material velocity check belongs ahead of any sizing decision on a [lack-of-fusion](https://www.therness.com/glossary/lack-of-fusion/) indication, not after one.

## Where you meet this term

- PAUT technique sheets and procedures, where each focal law in a scan sequence is listed with its angle and focus depth
- Instrument calibration and wedge delay verification, confirming a programmed delay set actually produces the intended beam
- Sizing and characterisation of a planar indication, where focus depth is chosen to place the beam waist at the reflector
- Probe and wedge qualification records, since a delay set is specific to one probe-wedge-material combination

## Related terms

[Lack of fusion](https://www.therness.com/glossary/lack-of-fusion/)

Lack of fusion is the absence of a fusion bond between weld metal and either the parent material or an adjacent weld pass, where the surfaces met without reaching fusion temperature.

## Standards that use this term

- [ISO 17640](https://www.therness.com/standards/iso-17640/)Does ISO 17640 govern the ultrasonic examination in front of you? Scope decision flow for the manual UT standard, the codes it is read with, and the records that support the result.

## Imperfections this term relates to

- [Incomplete fusion (ref. 401)](https://www.therness.com/defects/401-lack-of-fusion/)Lack of fusion and penetration — ISO 6520-1 group 4.
- [Gas pore (ref. 2011)](https://www.therness.com/defects/2011-porosity/)Cavities — ISO 6520-1 group 2.

[All glossary terms](https://www.therness.com/glossary/)