# Interpass temperature

Source: https://www.therness.com/glossary/interpass-temperature/
Language: en

Welding glossary

Interpass temperature is the temperature of the weld metal and adjacent parent material in a multi-run weld immediately before the next run is started.

Unit

°C (°F in ASME and AWS practice)

Full guide

[Interpass temperature: the long-form guide](https://www.therness.com/blog/interpass-temperature-welding-measurement-limits-control/)

This page defines the term. The guide works through how it is calculated, controlled and evidenced.

Interpass temperature is a *state* of the workpiece, not a setting on a machine, which is what makes it awkward to control and easy to violate. It is measured on the weld and the adjacent parent material immediately before the next run is deposited — not while the run is in progress, and not after the joint has been left to cool.

A maximum and a minimum exist for opposite reasons. The **minimum** — usually the preheat temperature — keeps the cooling rate slow enough to avoid hard, crack-prone microstructure and to let hydrogen diffuse out. The **maximum** keeps the joint from being held hot long enough to coarsen grain, soften the heat-affected zone or degrade toughness. Both bounds are material and thickness dependent, both are stated in the procedure, and the standards for measuring them are separate from the standards that set them.

The measurement itself is where most disputes start. A contact thermometer reads one point at one instant, and the point a welder can reach is not always the hottest region of the joint. Cadence matters too: on a fast multi-pass sequence a spot check between two runs can miss the interval when the workpiece was above the limit. Non-contact measurement across the whole run answers both objections, at the cost of needing the surface emissivity to be known before an absolute temperature can be trusted.

On thick-section work the practical failure is cumulative rather than dramatic: each run adds heat, the workpiece never returns to the assumed baseline, and the last runs of a joint are welded well above the band the qualification supports.

## Where you meet this term

- Welding procedure specifications, where a maximum and often a minimum are stated
- Multi-pass welds in thick section, where each run reheats the one before it
- Wire arc additive manufacturing, where the same control governs layer-to-layer heat accumulation
- Procedure qualification records, as a variable whose range the production weld must stay inside

## Related terms

[Heat input](https://www.therness.com/glossary/heat-input/)

Heat input is the energy delivered to a joint per unit length of weld, calculated from arc voltage, welding current and travel speed and multiplied by the thermal efficiency factor of the process.

[Emissivity](https://www.therness.com/glossary/emissivity/)

Emissivity is the ratio between the thermal radiation emitted by a real surface and that emitted by an ideal blackbody at the same temperature, expressed as a dimensionless value between zero and one.

## Standards that use this term

- [ASME BPVC Section IX](https://www.therness.com/standards/asme-ix/)ASME Section IX (BPVC Section 9) qualifies welding procedures (WPS, PQR) and welders (WPQ). When it applies, the codes that invoke it, and the records that prove it.

## Imperfections this term relates to

- [Gas pore (ref. 2011)](https://www.therness.com/defects/2011-porosity/)Cavities — ISO 6520-1 group 2.

## Applications where it is controlled

Pressure equipment and process plant

### [Weld monitoring for pressure vessels](https://www.therness.com/applications/pressure-vessels/)

Thick-section, multi-pass, code-governed welding. The codes that apply, the four monitoring pain points that cost pressure-vessel fabricators most, and which Therness signal addresses each.

Additive manufacturing and near-net-shape production

### [Monitoring for wire arc additive manufacturing](https://www.therness.com/applications/wire-arc-additive-manufacturing/)

WAAM is welding with no interpass inspection access and no wrought equivalent to compare against. The codes that apply, the four monitoring pain points, and which Therness signal addresses each.

[All glossary terms](https://www.therness.com/glossary/)