# Long-wave infrared (LWIR)

Source: https://www.therness.com/glossary/lwir/
Language: en

Welding glossary

Long-wave infrared (LWIR) is the infrared band, roughly 8 to 14 micrometres — an atmospheric transmission window carrying usable signal from near-ambient temperature up to several hundred degrees Celsius on a low-cost uncooled microbolometer, with less scattering from welding fume than shorter bands — and it is the band most industrial thermal cameras use.

Unit

Micrometres (µm), a wavelength

Full guide

[Long-wave infrared: the long-form guide](https://www.therness.com/blog/infrared-wavelength-bands-welding-thermography-swir-mwir-lwir/)

This page defines the term. The guide works through how it is calculated, controlled and evidenced.

Long-wave infrared, LWIR, is the band, roughly 8 to 14 micrometres, that industrial thermal cameras default to for a practical reason rather than a peak-emission one: it is an atmospheric transmission window that stays usable from near-ambient temperature up to several hundred degrees Celsius — the range a cooling weld, a heat-affected zone or an interpass surface actually sits in — on detectors that need no cryocooler and lose the least contrast to welding fume. It is not the band where those surfaces radiate most strongly: by Wien’s displacement law, a surface above roughly 90 °C already peaks below 8 micrometres, so a hot weld pool or the arc itself peaks well inside the short- or mid-wave band instead, not LWIR. LWIR wins the ambient-to-moderate range on cost, detector simplicity and fume tolerance, which is why it, not another band, is the default choice for weld and process [thermography](https://www.therness.com/glossary/thermography/).

Detector technology reinforces the choice. Most LWIR cameras used in industrial and welding settings are uncooled microbolometer arrays: no cryocooler, and lower cost and size than the cooled detectors older thermal-imaging systems needed, at the price of somewhat lower sensitivity and frame rate than a cooled sensor delivers. For monitoring a cooling bead or an interpass surface, that trade is favourable; for imaging an open arc directly, it is not, which is where [short-wave infrared](https://www.therness.com/glossary/swir/) takes over instead.

LWIR is the reason a “thermal camera” and a “welding camera” are frequently two different instruments on the same cell, a distinction covered fully under [infrared camera](https://www.therness.com/glossary/infrared-camera/): a visible or SWIR camera resolves the bright arc and pool, while a LWIR camera resolves the comparatively dim heat-affected zone around it, and neither band substitutes for the other. In [wire arc additive manufacturing](https://www.therness.com/applications/wire-arc-additive-manufacturing/), the same LWIR imaging that monitors a single weld extends naturally to layer-to-layer thermal accumulation, because the temperature range across a build stays inside the band LWIR is built for.

What an uncooled LWIR camera for a weld cell actually specifies (resolution, temperature range, thermal sensitivity and the interfaces it connects through) is set out on the [industrial thermal camera](https://www.therness.com/industrial-thermal-camera/) page.

As with any thermal measurement, an absolute-temperature reading from a LWIR camera still requires a known [emissivity](https://www.therness.com/glossary/emissivity/) for the surface in view — the wavelength band changes what can be seen, not the need to account for how the surface radiates.

## Where you meet this term

- Heat-affected-zone and interpass temperature thermal imaging
- Layer-to-layer thermal monitoring in wire arc additive manufacturing
- Passive thermographic weld inspection
- General industrial and building thermal imaging, outside welding

## Related terms

[Infrared camera](https://www.therness.com/glossary/infrared-camera/)

An infrared camera is an imaging instrument that converts the infrared radiation emitted by a scene into a two-dimensional map of apparent temperature, displayed as a thermal image.

[Short-wave infrared](https://www.therness.com/glossary/swir/)

Short-wave infrared (SWIR) is the infrared band immediately beyond visible light, roughly 0.9 to 1.7 micrometres by the common industrial convention (extended-range InGaAs detectors reach about 2.5 micrometres), used with narrow-band filtering to image very hot or self-luminous sources without the sensor saturating.

[Thermography](https://www.therness.com/glossary/thermography/)

Thermography is the use of infrared imaging to record and display the surface temperature distribution of an object as a two-dimensional thermal image, rather than a single-point temperature reading.

## Applications where it is controlled

Additive manufacturing and near-net-shape production

### [Monitoring for wire arc additive manufacturing](https://www.therness.com/applications/wire-arc-additive-manufacturing/)

WAAM is welding with no interpass inspection access and no wrought equivalent to compare against. The codes that apply, the four monitoring pain points, and which Therness signal addresses each.