Discover HeatCore AI

Welding glossary

Scanning plan (PAUT)

A PAUT scanning plan is the documented set of probe, wedge, focal-law, scan-path and coverage decisions fixed before scanning starts, so a phased array ultrasonic examination can be repeated by another operator and its coverage of the weld volume demonstrated afterward.

A phased array probe can be aimed, focused and swept electronically in ways a single-element probe cannot, and that flexibility is exactly why an undocumented PAUT setup is not repeatable: two operators can point nominally similar equipment at the same joint and cover different volumes of it without either one doing anything obviously wrong. A scanning plan is what removes that ambiguity, fixed on paper before scanning starts rather than decided as the operator goes.

Five items make a plan complete, and a document missing any one of them is a parameter list, not a scanning plan:

  • Joint geometry and thickness — the section that sets which wedge angles, probe frequency and aperture, and focal depth range are even physically capable of reaching the volume that needs examining.
  • Probe, wedge and focal-law set — the specific angles, aperture and focusing scheme programmed into the array, chosen to reach the joint fixed by the item above.
  • Index offset and scan surface — where the probe sits relative to the weld centreline, and which surface or surfaces of the joint are accessible for scanning; single-sided access changes what the rest of the plan can promise.
  • Coverage proof — a ray-trace or sound-path diagram showing that the root, both fusion faces and the cap are actually reached from every scan surface the plan uses, not merely that a wide range of angles was programmed.
  • Calibration block and reference sensitivity — the reflector set and sensitivity or time-corrected-gain curve the scan is set against, without which a recorded indication has no basis for comparison.

The reason coverage proof is its own item rather than folding into the focal-law set is that a technically valid set of angles can still miss a specific defect orientation on a specific joint geometry — a plan is only demonstrated complete when the ray-trace shows the root and both fusion faces are covered from the access actually available, which is precisely where lack of fusion and its sidewall variant hide when a scan plan is incomplete rather than the equipment being inadequate. The requirement that the scan plan itself be documented and validated before use sits in ISO 13588, the standard written specifically for automated and phased array ultrasonic technique; ISO 17640 covers manual technique and testing levels, and applies to automated equipment such as this only where the specification invokes testing level D. The personnel running and interpreting the scan hold their own competence qualification under ISO 9712, independent of the equipment being qualified.

Where you meet this term

  • Volumetric examination of full-penetration butt welds using automated or mechanised phased array equipment
  • Root and sidewall lack-of-fusion detection on pipeline and pressure-vessel girth welds
  • Procedure qualification for the examination itself, where the plan is validated against known reflectors before production scanning
  • Third-party and client witness inspections, where the scan plan is the document reviewed before scanning is watched