# Scanning plan (PAUT)

Source: https://www.therness.com/glossary/scanning-plan-paut/
Language: en

Welding glossary

A PAUT scanning plan is the documented set of probe, wedge, focal-law, scan-path and coverage decisions fixed before scanning starts, so a phased array ultrasonic examination can be repeated by another operator and its coverage of the weld volume demonstrated afterward.

Full guide

[Scanning plan (PAUT): the long-form guide](https://www.therness.com/blog/phased-array-ultrasonic-testing-paut-weld-inspection-guide/)

This page defines the term. The guide works through how it is calculated, controlled and evidenced.

A phased array probe can be aimed, focused and swept electronically in ways a single-element probe cannot, and that flexibility is exactly why an undocumented PAUT setup is not repeatable: two operators can point nominally similar equipment at the same joint and cover different volumes of it without either one doing anything obviously wrong. A scanning plan is what removes that ambiguity, fixed on paper before scanning starts rather than decided as the operator goes.

Five items make a plan complete, and a document missing any one of them is a parameter list, not a scanning plan:

- **Joint geometry and thickness** — the section that sets which wedge angles, probe frequency and aperture, and focal depth range are even physically capable of reaching the volume that needs examining.
- **Probe, wedge and [focal-law](https://www.therness.com/glossary/focal-law-paut/) set** — the specific angles, aperture and focusing scheme programmed into the array, chosen to reach the joint fixed by the item above.
- **Index offset and scan surface** — where the probe sits relative to the weld centreline, and which surface or surfaces of the joint are accessible for scanning; single-sided access changes what the rest of the plan can promise.
- **Coverage proof** — a ray-trace or sound-path diagram showing that the root, both fusion faces and the cap are actually reached from every scan surface the plan uses, not merely that a wide range of angles was programmed.
- **Calibration block and reference sensitivity** — the reflector set and sensitivity or time-corrected-gain curve the scan is set against, without which a recorded indication has no basis for comparison.

The reason coverage proof is its own item rather than folding into the focal-law set is that a technically valid set of angles can still miss a specific defect orientation on a specific joint geometry — a plan is only demonstrated complete when the ray-trace shows the root and both fusion faces are covered from the access actually available, which is precisely where [lack of fusion](https://www.therness.com/defects/401-lack-of-fusion/) and its [sidewall variant](https://www.therness.com/defects/4011-sidewall-lack-of-fusion/) hide when a scan plan is incomplete rather than the equipment being inadequate. The requirement that the scan plan itself be documented and validated before use sits in ISO 13588, the standard written specifically for automated and phased array ultrasonic technique; [ISO 17640](https://www.therness.com/standards/iso-17640/) covers manual technique and testing levels, and applies to automated equipment such as this only where the specification invokes testing level D. The personnel running and interpreting the scan hold their own competence qualification under [ISO 9712](https://www.therness.com/standards/iso-9712/), independent of the equipment being qualified.

## Where you meet this term

- Volumetric examination of full-penetration butt welds using automated or mechanised phased array equipment
- Root and sidewall lack-of-fusion detection on pipeline and pressure-vessel girth welds
- Procedure qualification for the examination itself, where the plan is validated against known reflectors before production scanning
- Third-party and client witness inspections, where the scan plan is the document reviewed before scanning is watched

## Related terms

[Phased array ultrasonic testing](https://www.therness.com/glossary/phased-array-ultrasonic-testing-paut/)

Phased array ultrasonic testing is a volumetric NDT method that fires a linear array of ultrasonic elements with programmable time delays to steer and focus the beam electronically, producing a sectorial image of a weld cross-section from a single probe position.

[Focal law](https://www.therness.com/glossary/focal-law-paut/)

A focal law is the calibrated set of per-element time delays applied to a phased array probe so the pulses from every element combine into one ultrasonic beam steered to a chosen angle and focused at a chosen depth in the part.

## Standards that use this term

- [ISO 17640](https://www.therness.com/standards/iso-17640/)Does ISO 17640 govern the ultrasonic examination in front of you? Scope decision flow for the manual UT standard, the codes it is read with, and the records that support the result.
- [ISO 9712](https://www.therness.com/standards/iso-9712/)Does ISO 9712 certify the person performing your examination? Scope decision flow for the NDT personnel standard, the roles it does not cover, and the records that survive an audit.

## Imperfections this term relates to

- [Incomplete fusion (ref. 401)](https://www.therness.com/defects/401-lack-of-fusion/)Lack of fusion and penetration — ISO 6520-1 group 4.
- [Sidewall lack of fusion (ref. 4011)](https://www.therness.com/defects/4011-sidewall-lack-of-fusion/)Lack of fusion and penetration — ISO 6520-1 group 4.

## Applications where it is controlled

Pressure equipment and process plant

### [Weld monitoring for pressure vessels](https://www.therness.com/applications/pressure-vessels/)

Thick-section, multi-pass, code-governed welding. The codes that apply, the four monitoring pain points that cost pressure-vessel fabricators most, and which Therness signal addresses each.

[All glossary terms](https://www.therness.com/glossary/)