# Thermal imaging frame rate

Source: https://www.therness.com/glossary/thermal-imaging-frame-rate/
Language: en

Welding glossary

Thermal imaging frame rate is the number of infrared images a thermal camera reads out from its detector each second, in hertz; the time between two consecutive images is its reciprocal.

Unit

Hz (frames per second); the frame interval is its reciprocal

Formula

Frame interval = 1 ÷ frame rate; frames inside an event ≈ frame rate × event duration, rounded down or up depending on when the event starts

[t8/5 cooling time calculator](https://www.therness.com/tools/t85-cooling-time-calculator/)

Full guide

[Thermal imaging frame rate: the long-form guide](https://www.therness.com/blog/weld-cooling-rate-measurement-thermography-t85/)

This page defines the term. The guide works through how it is calculated, controlled and evidenced.

A frame is one thermal image, and the frame rate counts how many of them the detector delivers each second. A camera at 25 Hz returns a new image every 40 ms. EN 16714-2:2016 covers infrared cameras used for thermographic non-destructive testing. Its clause 4.2.5 describes frame rate as the number of frames read out from the detector per time unit, and the formal terms sit in EN 16714-3. The same clause notes that a windowed, reduced frame can raise the rate, so check which frame size a quoted figure refers to.

EN 16714-2 lists frame rate among the parameters the manufacturer has to provide, beside thermal resolution, spatial resolution and temporal resolution. It adds that integration time, read-out mode and response time can also affect the maximum frame rate, and it says temporal resolution matters for capturing moving objects and fast temperature changes. The standard is written for thermographic testing cameras. It is a source for what the parameter means, not a frame-rate requirement for weld monitoring.

## Worked example: frame rate or a channel’s sampling rate?

A neighbouring term on a weld record is the sampling rate of an electrical channel: how many values per second a data acquisition unit records on one channel. Both are rates, which makes the two figures easy to set side by side. Take a cell that records thermal frames and one electrical channel together, each at its maximum (an illustrative pairing): a camera specified at up to 25 Hz over Ethernet, as [HeatCam IR-C](https://www.therness.com/products/heatcam-ir-c/) is, and an acquisition unit sampling at up to 25 kHz per channel, as [WeldTrace](https://www.therness.com/products/therness-weldtrace/) does.

- A frame is a whole image and arrives every 40 ms. A sample is one value on one channel and arrives every 40 µs, so one frame interval holds 1,000 samples.
- A 2 s cooling interval (illustrative) spans about 50 frames and 50,000 samples. A 5 ms arc event (also illustrative) spans about 125 samples but can fall between two frames, so no frame is read out while it happens.

Neither rate stands in for the other. The electrical record says nothing about where the heat is, and the thermal frames do not record what the machine delivered.

The [guide to cooling-rate measurement by thermography](https://www.therness.com/blog/weld-cooling-rate-measurement-thermography-t85/) recommends setting the frame rate from the shortest interval the measurement must resolve and recording it with the data. For [t8/5](https://www.therness.com/glossary/cooling-time-t8-5/), several frames should fall inside the interval on the fastest joint.

## Where you meet this term

- Camera selection for thermographic testing, where EN 16714-2 lists frame rate among the parameters the manufacturer provides, beside thermal, spatial and temporal resolution
- Cooling-rate measurements such as t8/5, where the frame interval limits how closely the two temperature crossings can be placed
- Tracking a moving heat source, where the distance travelled between frames is the travel speed divided by the frame rate
- Recorded sequences, where the frame rate belongs with the data so a later reader knows how closely an event was sampled

## Related terms

[Thermal imaging](https://www.therness.com/glossary/thermal-imaging/)

Thermal imaging is the capture and display of infrared radiation from a scene as a two-dimensional image whose pixels represent apparent temperature or radiation intensity. In welding, it shows where heat is distributed across the pool, bead and nearby material.

[Infrared camera](https://www.therness.com/glossary/infrared-camera/)

An infrared camera is an imaging instrument that converts the infrared radiation emitted by a scene into a two-dimensional map of apparent temperature, displayed as a thermal image.

[Thermography](https://www.therness.com/glossary/thermography/)

Thermography is the use of infrared imaging to record and display the surface temperature distribution of an object as a two-dimensional thermal image, rather than a single-point temperature reading.

[Cooling time t8/5](https://www.therness.com/glossary/cooling-time-t8-5/)

Cooling time t8/5 is the time a weld and its heat-affected zone take to cool from 800 °C to 500 °C, the interval in which austenite decomposes and the resulting microstructure is fixed.

[All glossary terms](https://www.therness.com/glossary/)