ISO 13916 answers a narrower question than it is often credited with: not what preheat or
interpass temperature a joint needs, but how a reading taken
at the joint is to be trusted. It covers both contact methods — thermocouples,
temperature-indicating crayons — and non-contact methods such as infrared thermometers and
thermal imaging, and it applies to the preheat check before arc-strike, the interpass check
between passes, and the preheat maintenance check on a joint held at temperature between
operations.
The recurring confusion is treating it as a source of numbers. It is not. Preheat and interpass
values come from the WPS, the material or application standard, or a method such as
EN 1011-2; ISO 13916 only governs whether the reading taken against
that value can be relied on.
A single-point contact check is blind to a cold patch elsewhere on the joint: a reading taken at
one location says nothing about a spot on the far side of a long seam. That is why a full-field
thermal image is the more defensible record on a long or awkward-access joint, and why the
choice between a point method and a full-field method is a decision the WPS or inspection plan
should state, not one left to whichever device happens to be on hand.
Because hydrogen cracking and porosity both trace back to
heat that was assumed rather than confirmed, the record a measurement leaves matters as much as
the reading itself. Therness thermal equipment captures preheat and interpass across the whole
joint on every pass and exports a per-weld record a welding coordinator can attach to the job
file, rather than a spot value taken on trust. Where preheat itself still needs sizing before a
reading can be checked against it, the preheat temperature calculator
covers that input, and ISO 3834-2 is the quality-system standard that
requires the preheat record this measurement produces to exist at all.
Conformity is decided by inspection and testing against the criteria the standard and the
contract set. The records below are evidence that the process was held where it was
qualified; they support an inspection result, they never replace one.