Discover HeatCore AI

ISO standard · reference card

ISO 14175: scope, designation and what it does not set

Does ISO 14175 classify the shielding or backing gas your WPS names? Scope decision flow for the gas classification standard, and where it stops short of setting flow rate.

Designation
ISO 14175
Issued by
ISO
Title
Welding consumables — Gases and gas mixtures for fusion welding and allied processes
Edition
Confirm the edition your WPS or purchase specification cites.

ISO 14175 answers a narrower question than it is often asked to: it classifies and designates a shielding or backing gas, and stops there. Flow rate, nozzle standoff and coverage adequacy are procedure decisions left to the WPS and to ISO 15609-1 — a common misreading treats the classification as if it also settled how the gas should be applied.

The designation exists so a WPS does not have to reference a brand name. A trade name identifies a supplier’s marketed blend; the ISO 14175 designation identifies the classification that blend falls into, and that designation — not the trade name — is what a qualification range is written against. Re-qualifying a WPS because a supplier renamed a product, with no classification change, is a cost this standard prevents.

Shielding gas loss is a common named cause behind porosity, and one of the least visible from outside the arc. Therness’s shielding gas flow calculator turns a flowmeter reading into consumption and coverage figures, and WeldTrace records the flow actually delivered for the pass rather than the regulator’s setpoint.

Scope: does it apply to your job?

Applies to

  • Classification and designation of gases and gas mixtures for shielding, backing, process or assist duty in arc, plasma or laser welding, arc braze welding, and plasma or laser cutting
  • The reference a WPS cites for the gas, in place of a supplier trade name alone
  • Gas as delivered by the supplier — purity and mixing tolerances are specified at delivery, not point of use

Does not apply to

  • Fuel gases for oxy-fuel welding and cutting, and gas-laser resonator gases
  • Selecting the flow rate for a joint — that is a WPS decision, not this standard's scope
  • Issuing the supplier's certificate — it references this classification, the standard does not certify

Applicability decision flow

Four questions that decide whether ISO 14175 governs the joint
QuestionIf yesIf no
Is the gas a shielding, backing, process or assist gas for arc, plasma or laser welding, arc braze welding, or plasma or laser cutting?ISO 14175 is the classification standard to cite.Fuel gases (acetylene, natural gas, propane) and gas-laser resonator gases fall outside this standard.
Does the WPS name the gas by an ISO 14175 designation rather than a trade name alone?Verify the supplier's certificate matches that designation, not just the marketed blend name.Agree the designation and write it into the WPS before qualification — the qualified range is tied to the classification, not to the cylinder in stock.
Does the joint use a separate backing gas as well as a shielding gas?Both roles are classified under the same scheme; record which designation fills which role.Confirm the shielding gas designation alone is what the qualification record covers.

What proves conformity, and what only supports it

Conformity is decided by inspection and testing against the criteria the standard and the contract set. The records below are evidence that the process was held where it was qualified; they support an inspection result, they never replace one.

Requirements of ISO 14175 and the Therness record that evidences each
RequirementRecord producedSource
Recording the shielding gas flow actually delivered for the pass, not the regulator's set pointGas flow acquired alongside current, voltage and wire feed speed at the same per-pass timestampWeldTrace
Joining the gas channel with the rest of the process record into one exportable per-weld fileTimestamped process export tied to weld identifier and WPS referenceHeatCore AI

Questions engineers ask about ISO 14175

Does ISO 14175 set the flow rate to use for a given joint?

No. Flow rate is a WPS decision built around the joint and process; ISO 14175 only classifies and designates the gas itself.

Can a WPS just name a trade name for the shielding gas?

A trade name identifies a supplier's product, not a classification. The safer entry is the ISO 14175 designation, since that is what a requalification range is written against.

Does this standard cover oxy-fuel cutting gas?

No. ISO 14175 classifies gases for arc, plasma or laser welding, arc braze welding, and plasma or laser cutting; oxy-fuel gases sit outside its scope.

Evidence the process, not just the paperwork

Therness records what the machine actually delivered on every weld — parameters, thermal signature and a per-weld trail — so a conformity argument rests on measurements instead of recollection.

Progetto cofinanziato nell'ambito del PR Piemonte FSE+ 2021-2027,