# ISO 17641-1: scope of hot cracking test methods

Source: https://www.therness.com/standards/iso-17641-1/
Language: en

ISO standard · reference card

Does ISO 17641-1 govern your susceptibility test? Scope decision flow for the general part of the hot cracking test series, the codes it sits next to, and what a pass does not prove.

Designation

ISO 17641-1

Issued by

ISO

Title

Destructive tests on welds in metallic materials — Hot cracking tests for weldments — Arc welding processes — Part 1: General

Edition

Confirm the edition your test programme cites.

ISO 17641-1 is not itself a test. It is the general part of a series, carrying the terms, principles and requirements that the actual hot cracking test methods in Parts 2 and 3 build on — self-restraint tests in Part 2, externally loaded tests in Part 3. Hot cracking here means solidification or liquation cracking that forms while the weld pool and the adjacent zone are still hot, the mechanism a series like this is built to provoke and measure under controlled conditions rather than to leave to chance in production.

The recurring confusion is treating a susceptibility test as a production acceptance test. It is not. A combination that passes tells a fabricator that material, consumable and process choice are unlikely to crack under the restraint or loading the test applied — a useful input to procedure development, not a substitute for inspecting the joint that actually gets welded. Production restraint and heat input rarely match a test piece exactly, and a crack found in service is still judged under the quality-level standard regardless of what a susceptibility test showed earlier.

Therness equipment does not run a susceptibility test. It measures the conditions a test result is meant to inform — heat input from measured current, voltage and travel speed, and continuous weld-pool geometry through the pass — so a procedure decision rests on real production data, not a settings sheet. See [ISO 17642-1](https://www.therness.com/standards/iso-17642-1/) for the equivalent series covering cold cracking, and [ISO 6520-1](https://www.therness.com/standards/iso-6520-1/) for how an eventual crack finding gets its reference number.

## Scope: does it apply to your job?

### Applies to

- General principles, terminology and requirements common to the ISO 17641 series of hot cracking susceptibility tests for weldments
- Arc welding processes
- Selecting between the self-restraint tests of Part 2 and the externally loaded tests of Part 3

### Does not apply to

- Cold (hydrogen) cracking susceptibility testing — the ISO 17642 series covers that mechanism
- Accepting or rejecting a production weld that contains a crack — a quality-level standard governs that, and a crack there is a nonconformance regardless of any susceptibility test result
- Welding processes outside arc welding

## Applicability decision flow

Four questions that decide whether ISO 17641-1 governs the joint

| Question | If yes | If no |
| --- | --- | --- |
| Is the question whether a material, consumable and process combination is susceptible to hot (solidification or liquation) cracking? | The ISO 17641 series is the applicable test-method family; Part 1 carries the terms and general requirements the other parts assume. | Cold (hydrogen) cracking susceptibility is covered by the ISO 17642 series instead. |
| Does the test rely on the test piece's own restraint, with no external load applied during welding? | A self-restraint test, covered in Part 2 of the series. | An externally loaded test, covered in Part 3 of the series. |
| Is the process being qualified an arc welding process? | The series applies directly. | The series is written for arc welding; a different process needs a different test basis. |
| Is the outcome needed a pass/fail acceptance of a production weld? | The test characterises susceptibility under controlled conditions, not production acceptance — a crack found in service is still judged under the quality-level standard. | The result supports material, consumable or procedure selection ahead of production. |

## What proves conformity, and what only supports it

Conformity is decided by inspection and testing against the criteria the standard and the contract set. The records below are evidence that the process was held where it was qualified; they support an inspection result, they never replace one.

Requirements of ISO 17641-1 and the Therness record that evidences each

| Requirement | Record produced | Source |
| --- | --- | --- |
| Providing the measured heat input and interpass record that supports a procedure decision informed by a hot cracking test result | Arc energy computed per pass from measured current, voltage and travel speed, not nominal figures | WeldTrace |
| Flagging a weld-pool or solidification-pattern anomaly during production worth relating back to the susceptibility a test characterised | Continuous weld pool geometry captured through the full pass | PoolDrop |

- [WeldTrace](https://www.therness.com/products/therness-weldtrace/)
- [PoolDrop](https://www.therness.com/products/therness-pooldrop/)

## Standards read alongside this one

- ISO 17641-2The self-restraint hot cracking test methods in the same series.
- ISO/TR 17641-3The externally loaded hot cracking test methods in the same series, published as a Technical Report.
- [ISO 17642-1](https://www.therness.com/standards/iso-17642-1/)The equivalent general part for the cold-cracking series, testing a different cracking mechanism.
- [ISO 6520-1](https://www.therness.com/standards/iso-6520-1/)Supplies the reference number for a hot crack once one is found.

## Terms used on this page

[Weld pool](https://www.therness.com/glossary/weld-pool/)

The weld pool is the localized volume of molten metal created by the welding heat source, into which filler metal is added and from which the weld bead forms as it solidifies.

## Where this standard is applied

Structural steel fabrication and erection

### [Weld monitoring for structural steel fabrication](https://www.therness.com/applications/structural-steel/)

Shop-fabricated and site-erected steel under AWS D1.1 and EN 1090-2. The four monitoring pain points that cost structural fabricators most, and which Therness signal addresses each.

Offshore oil, gas and marine energy structures

### [Weld monitoring for offshore structures and pipelines](https://www.therness.com/applications/offshore/)

Fixed platforms, topside piping and subsea pipelines welded under classification-society rules and the transportation codes. The pain points that cost offshore fabricators most, and which Therness signal addresses each.

## Evidence the process, not just the paperwork

Therness records what the machine actually delivered on every weld — parameters, thermal signature and a per-weld trail — so a conformity argument rests on measurements instead of recollection.

[Book a technical call](https://www.therness.com/contact/) [See the monitoring platform](https://www.therness.com/welding-monitoring-system/)