Reference 4013 narrows reference 401 to the root: the pass with the most restricted access, the
tightest tolerance for heat input, and the least room to recover once it is covered. It differs
from reference 402, lack of penetration, in one precise way — penetration asks whether the arc
melted through the parent metal at all, while 4013 asks whether the root pass then fused to the
root faces or to backing.
Most causes trace to one operator pattern: running the root pass cold on purpose to guard
against burn-through, which trades one imperfection for another. The rest are fit-up conditions
— gap, backing alignment, root face land — that restrict arc access or push toward that same
cold-running response.
Root-pass monitoring earns unusual attention because it is the one point in the joint where a
camera view of pool wetting watches the exact event a later reference number will describe,
rather than a proxy for it.
See reference 401, lack of fusion, in general; reference 4011,
lack of sidewall fusion, the counterpart at the bevel;
and reference 402, lack of penetration.
The column that matters most is the last one. An inspection family marked as not finding
this imperfection will not find it however carefully it is applied, and planning around
that is cheaper than discovering it during a final examination.
Therness pages never reproduce a standard's acceptance values: those tables are
copyrighted and belong in the copy you hold. What follows is the pointer — which document
governs, and which part of it to open.