Thermal imaging frame rate

Thermal imaging frame rate is the number of infrared images a thermal camera reads out from its detector each second, in hertz; the time between two consecutive images is its reciprocal.

Unit
Hz (frames per second); the frame interval is its reciprocal
Formula
Frame interval = 1 ÷ frame rate; frames inside an event ≈ frame rate × event duration, rounded down or up depending on when the event starts

A frame is one thermal image, and the frame rate counts how many of them the detector delivers each second. A camera at 25 Hz returns a new image every 40 ms. EN 16714-2:2016 covers infrared cameras used for thermographic non-destructive testing. Its clause 4.2.5 describes frame rate as the number of frames read out from the detector per time unit, and the formal terms sit in EN 16714-3. The same clause notes that a windowed, reduced frame can raise the rate, so check which frame size a quoted figure refers to.

EN 16714-2 lists frame rate among the parameters the manufacturer has to provide, beside thermal resolution, spatial resolution and temporal resolution. It adds that integration time, read-out mode and response time can also affect the maximum frame rate, and it says temporal resolution matters for capturing moving objects and fast temperature changes. The standard is written for thermographic testing cameras. It is a source for what the parameter means, not a frame-rate requirement for weld monitoring.

Worked example: frame rate or a channel’s sampling rate?

A neighbouring term on a weld record is the sampling rate of an electrical channel: how many values per second a data acquisition unit records on one channel. Both are rates, which makes the two figures easy to set side by side. Take a cell that records thermal frames and one electrical channel together, each at its maximum (an illustrative pairing): a camera specified at up to 25 Hz over Ethernet, as HeatCam IR-C is, and an acquisition unit sampling at up to 25 kHz per channel, as WeldTrace does.

  • A frame is a whole image and arrives every 40 ms. A sample is one value on one channel and arrives every 40 µs, so one frame interval holds 1,000 samples.
  • A 2 s cooling interval (illustrative) spans about 50 frames and 50,000 samples. A 5 ms arc event (also illustrative) spans about 125 samples but can fall between two frames, so no frame is read out while it happens.

Neither rate stands in for the other. The electrical record says nothing about where the heat is, and the thermal frames do not record what the machine delivered.

The guide to cooling-rate measurement by thermography recommends setting the frame rate from the shortest interval the measurement must resolve and recording it with the data. For t8/5, several frames should fall inside the interval on the fastest joint.

Where you meet this term

  • Camera selection for thermographic testing, where EN 16714-2 lists frame rate among the parameters the manufacturer provides, beside thermal, spatial and temporal resolution
  • Cooling-rate measurements such as t8/5, where the frame interval limits how closely the two temperature crossings can be placed
  • Tracking a moving heat source, where the distance travelled between frames is the travel speed divided by the frame rate
  • Recorded sequences, where the frame rate belongs with the data so a later reader knows how closely an event was sampled