Free tool · no sign-up
Weld drawing tolerance checker
EN ISO 13920 sets general tolerances for welded constructions, and a drawing that invokes it names a tolerance class for its length dimensions and for its angles. The permitted deviation for a given nominal range is read from that class in the edition the drawing cites. This page does not hold those values: you copy the deviation from the drawing and the checker tests one measurement against it.
The default is a worked arithmetic example: a 300 mm dimension with a permitted deviation of ± 2 mm, measured at 300.80 mm, which sits 1.20 mm inside the band. The 2 mm figure is training data for the example and not a tolerance taken from the standard. Switch to Imperial to see the same inputs and output in inches.
The band is entered first, then the arithmetic is checked
Length band: lower = nominal − deviation, upper = nominal + deviation
Length margin: the smaller of (measured − lower) and (upper − measured)
Angle band: deviation in degrees = arcminutes ÷ 60
A non-negative margin sits inside the band; the badge names the dimension it covers.
The class names and the general scope come from ISO's official EN ISO 13920 record. The permitted numbers for each class and nominal range stay in the standard and on the drawing; they are not reproduced on this page. The class letter you select is written into the result so the arithmetic can be traced back to the callout it came from.
How to check a welded dimension against its drawing tolerance
From drawing callout to a recorded margin, one dimension at a time.
- Read the callout. Take the nominal dimension, the tolerance class and the edition cited on the drawing. Confirm the drawing invokes EN ISO 13920 general tolerances before applying its class.
- Confirm the edition. Note which edition of the standard the drawing cites, and copy the permitted deviation from that edition or from the drawing itself.
- Enter the band. Type the nominal dimension and the permitted deviation into the matching check. A length is compared in millimetres or inches; an angle is compared in degrees with an arcminute deviation.
- Enter the measurement. Type the measured value in the same unit system. The result shows the permitted limits, the measured deviation and the margin to the nearest limit.
- Repeat and record. Check every other dimension on the drawing separately. A pass here covers one dimension only, and the measurement record still carries the temperature and the method used.
- One dimension per verdict. A length check says nothing about an angle on the same weld. Work through the callouts one at a time, and keep the checked list next to the drawing with the weld map so a re-check finds the same weld number.
- Before the dimension, the joint. Sizing, throat and preparation decisions belong upstream of the tolerance check: use the fillet weld size calculator for a fillet throat and the WPS variables checklist for the procedure record.
- Temperature is a record, not a correction. Clause 6.1 of the standard flags measurement temperature as an influence on the result. Write the temperature beside the measurement and let the inspection plan decide whether it matters.
For the class-to-dimension workflow and how the tolerance classes are laid out, read the ISO 13920 tolerance guide.
Questions engineers ask about this calculation
Does this checker supply the ISO 13920 tolerance values?
No. Every permitted deviation on this page is one you enter from the drawing or from the licensed edition the drawing cites. The checker keeps the dimension, the band and the measurement in one place and does the arithmetic; it does not reproduce a tolerance table, so the values stay attached to the document that authorised them.
Which edition of the standard should I read?
The one the drawing cites. Confirm that edition on the drawing before copying a deviation, because the tolerance a reader takes from a different edition may not be the one the design office applied. The checker records nothing about editions and assumes nothing about them.
Why are length and angle checked separately?
They are separate tolerance tables and separate drawing callouts. A length can sit inside its band while an angle on the same weld sits outside its own, so each dimension is checked on its own and reported with its own margin. Filling only one set of fields leaves the other check switched off, and the page says which one did not run.
How should the measurement temperature be handled?
Record it. ISO 13920 clause 6.1 notes that an unusual measurement temperature can influence the result, and the correct treatment belongs to the inspection plan, not to a hidden correction inside a web page. The checker works on the numbers you enter and leaves the temperature decision with the measurement record.
Keep the measurement evidence with the weld
WeldTrace records welding parameters for each pass. Those records support traceability and investigation; they do not replace the dimensional inspection or the drawing tolerance decision.