Discover HeatCore AI

Welding glossary

Eddy current testing (ECT)

Eddy current testing (ECT) is a non-destructive method in which a coil probe induces eddy currents in an electrically conductive part and the instrument reads how a discontinuity changes the probe's response. For welds, ISO 17643 applies it to surface-breaking and near-surface planar discontinuities, mainly in ferritic materials.

Eddy current testing passes an alternating current through a coil in a probe moved over the weld surface. The changing magnetic field induces eddy currents in the conductive metal beneath, and a discontinuity changes how those currents flow. The instrument shows the change as a signal that is evaluated on the complex plane, the analysis named in the title of ISO 17643:2015: “by complex-plane analysis”.

ISO 17643 defines the technique for surface-breaking and near-surface planar discontinuities, mainly in ferritic materials: weld metal, heat-affected zones and parent metal. It can also be specified for non-ferritic materials, for example in an application standard. It can be applied to coated and uncoated objects, in fabrication and in service. Testing is usually done in the as-welded condition, but very rough surface finishes can affect accuracy. Because the method reaches only the surface and the zone just beneath it, a flaw buried in the weld is a job for a volumetric method such as phased array ultrasonic testing.

Worked example: a trace you read, a signal you interpret

A weld toe on ferritic structural steel is examined twice for surface cracks.

  • With magnetic particle testing, the examiner sees a trace of powder on the part, measures it and classes it as a linear indication or a non-linear one.
  • With ECT, nothing is visible on the part. The probe scans the toe and the instrument displays a signal, which the operator evaluates on the instrument instead of reading it off the part.

Now ask the same question of an aluminium weld. Magnetic particle testing cannot be used there: it needs a magnetisable part, and ISO 23278, its acceptance-level standard, is written for ferromagnetic steel welds. ECT needs a conductive part, not a magnetisable one. ISO 17643 is written mainly for ferritic materials and says non-ferritic use can be specified, for example in an application standard. So on an aluminium weld ECT can be used when a specification calls for it.

Neither result describes how the weld was made. ECT reports the surface and near-surface condition at the moment of testing, and the parameters and thermal history behind the joint are a separate record.

Where you meet this term

  • Detection of surface-breaking and near-surface planar discontinuities in the weld metal, heat-affected zones and parent metal of ferritic steel, the case ISO 17643 is mainly written for
  • Examination of coated or uncoated welds in fabrication and in service, both of which ISO 17643 names
  • Welds in non-ferritic materials, when a specification such as an application standard calls for ECT
  • NDT reports where the finding is an instrument signal, not a visible trace

Progetto cofinanziato nell'ambito del PR Piemonte FSE+ 2021-2027,
Priorità I, Obiettivo Specifico a), Azione 4 – "Sostegno alla nascita delle start up"