Radiographic testing weld acceptance criteria determine whether a completed weld is fit for service — yet the thresholds, defect categories, and reference zones differ substantially between ISO 10675-1, ASME Section VIII, ASME B31.3, API 1104, and AWS D1.1. A porosity cluster that passes API 1104 may fail ASME B31.3 severe cyclic requirements; an incomplete penetration indication that is rejectable in ISO 10675-1 Level 1 may be evaluated differently under AWS D1.1 statically loaded criteria. This guide gives welding engineers, quality managers, and NDT Level 2 interpreters a code-by-code breakdown of RT acceptance limits, a standards comparison table, common interpretation failure modes, and the ISO 3834 documentation chain required for compliant weld records.

Key Takeaways

  • ISO 10675-1 is the dedicated European RT acceptance standard for metallic welds — its three levels (1, 2, 3) map directly to ISO 5817 quality levels B, C, and D.
  • ASME Section VIII UW-51 governs pressure vessel RT acceptance: cracks and lack of fusion are categorically rejectable; porosity and slag use absolute dimension limits tied to weld thickness.
  • ASME B31.3 process piping has its own weld acceptance criteria, Table 341.3.2-1 (Table 341.3.2 before the 2024 edition), not the Section VIII UW-51 criteria; Normal Fluid Service requires random RT or UT of at least 5% of circumferential butt and miter groove welds, and a defect in the sample triggers progressive examination.
  • API 1104 Section 9 combines absolute length limits with a density-based area criterion for rounded indications in pipeline girth welds — a calculation method absent from ASME or ISO codes.
  • AWS D1.1 Clause 6 sets stricter linear-indication rejection (any crack or lack of fusion regardless of length) plus combined-length limits for porosity over any 300 mm weld zone.
  • RT detects volumetric defects — porosity, inclusions, lack of penetration, burn-through — but can miss planar defects oriented perpendicular to the beam; PAUT is often specified alongside RT for critical joints.
  • Every RT interpretation record must include the level 2 certificate, procedure reference, IQI identity, and weld traceability to meet ISO 3834 and EN 1090 documentation requirements.

Table of Contents

What RT Acceptance Criteria Actually Measure

Radiographic testing uses ionising radiation — X-rays or gamma rays — to project a shadow image of the weld cross-section onto a detector (film or digital panel). Denser, thicker material attenuates the beam more strongly; voids, inclusions, and low-density defects appear as regions of higher exposure (dark areas on film, bright regions in digital radiographs).

Acceptance criteria define the maximum permissible indication characteristics an interpreter may allow before condemning a weld for repair or rejection. Every code measures two or more of the following:

  • Indication type: crack, lack of fusion, incomplete penetration, porosity, slag, tungsten inclusion — each category typically receives a separate limit
  • Individual dimension: length or diameter of a single indication measured on the radiograph
  • Accumulated length: sum of individual indication lengths within a defined reference zone (commonly 150 mm or 300 mm)
  • Area density: ratio of defect area to a reference area (used by API 1104 for rounded indications)
  • Fraction of weld thickness: some codes express limits as a proportion of the weld thickness rather than an absolute dimension

What RT cannot reliably detect: planar defects oriented perpendicular to the X-ray beam (transverse cracks, sidewall lack of fusion at high bevel angles) can escape detection because they present minimal thickness change in the beam direction. EN ISO 17636-1 Class B technique improves geometry by using finer focal spots and longer source-to-film distances, increasing sensitivity — but RT remains a volumetric method. For planar defect detection, phased-array ultrasonic testing (PAUT) is the complementary tool.

Weld thickness is the primary variable that RT acceptance criteria track. The code tables typically step through thickness ranges (e.g., <6 mm, 6–12 mm, 12–25 mm, 25–50 mm, >50 mm) and set tighter absolute limits in thinner sections where a given indication occupies a larger fraction of the joint cross-section.

ISO 10675-1 and ISO 5817 — The European Framework

ISO 10675-1 (Acceptance levels for radiographic testing — Part 1: steel, nickel, titanium and their alloys) is the European and international standard that translates the ISO 5817 weld quality levels B, C, and D into concrete RT acceptance thresholds. It is the primary acceptance reference wherever EN 1090-2 structural execution or ISO 3834 quality requirements govern fabrication.

Acceptance Level Mapping

ISO 10675-1 LevelISO 5817 EquivalentTypical Application
Level 1Quality Level B (stringent)Fatigue-critical joints, EXC3/4 structures, pressure-bearing welds
Level 2Quality Level C (intermediate)General structural fabrication, EXC2 under EN 1090-2
Level 3Quality Level D (lenient)Non-structural or low-load applications, EXC1

The acceptance limit table in ISO 10675-1 follows the same discontinuity taxonomy as ISO 5817: cracks (100) and lack of fusion (401) are categorically rejectable at all three levels — no maximum dimension applies; the presence of the indication is itself the rejection criterion.

For porosity:

  • Level 1: maximum pore diameter 0.25×t (minimum 0.5 mm, maximum 3 mm for t = 12 mm); maximum total projected pore area in any 100 mm × t zone is 1% of the zone area
  • Level 2: maximum pore diameter 0.5×t (minimum 1 mm, maximum 4 mm); total projected area up to 2% of the zone
  • Level 3: maximum pore diameter 1×t (minimum 1.5 mm, maximum 6 mm); total projected area up to 4% of the zone

ISO 10675-1 uses a 100 mm reference length for porosity density calculations. ASME and API codes use different reference zones — always check which standard governs before applying a limit from another code.

For elongated indications (slag inclusions, tungsten inclusions):

  • Level 1: maximum length 0.5×t (minimum 1.5 mm, maximum 6 mm for t > 12 mm); maximum sum of indication lengths in 12t zone < 2t
  • Level 2: maximum 1×t (minimum 2 mm, maximum 8 mm); sum < 4t in 12t zone
  • Level 3: maximum 2×t (minimum 3 mm, maximum 16 mm); sum < 8t in 12t zone

Incomplete penetration (ICP / lack of penetration) is rejectable at Level 1 by ISO 5817. At Levels 2 and 3, ISO 5817 permits ICP under specific dimensional limits; ISO 10675-1 then translates these into radiographic indication limits, though many project specifications choose to reject ICP categorically regardless of level.

ASME Acceptance Criteria — Pressure Vessels and Piping

ASME Section VIII Division 1 — Pressure Vessels (UW-51 and UW-52)

ASME BPVC Section VIII Division 1 governs pressure vessel construction. Welds in Category A and B joints (longitudinal and circumferential seams) that require RT examination are evaluated against UW-51 for 100% radiography or UW-52 for spot radiography.

Under UW-51, the following are categorically rejectable:

  • Any crack or zone of incomplete fusion (including lack of penetration for groove welds where full penetration is specified)
  • Any incomplete penetration in butt welds in vessels under ASME Section VIII that are built to UW-51 requirements

For slag inclusions (elongated indications), the rejection limits (UW-51(b)(2)) are:

Weld thickness (t)Maximum individual lengthMaximum sum in 150 mm zone
t < 19 mm6 mm2t
19 mm ≤ t < 57 mmt/32t
t ≥ 57 mm19 mm2t

For rounded indications (porosity), ASME Section VIII References ASME BPVC Section V Appendix 4 (for film radiography) and Appendix 10 (for digital RT). These appendices specify maximum pore diameters and chart-based density limits for individual and clusters of rounded indications.

UW-52 (spot RT) applies when only spot examination is required. Each spot-examined weld length typically represents a production lot. If a spot examination fails, two additional welds must be examined; if either of those fails, 100% of the lot requires examination. ASME B31.3 applies its own progressive sampling rule (para. 341.3.4, below); ISO 10675 has no direct equivalent.

ASME B31.3 — Process Piping

ASME B31.3 references ASME BPVC Section V for RT technique, but it does not use the Section VIII UW-51 acceptance criteria. Welds are judged against its own Table 341.3.2-1 (Table 341.3.2 before the 2024 edition), which has a column per fluid service and limits that differ by column. The degree of required examination also depends on fluid service category:

  • Category D: visual examination only (para. 341.4.2); no RT or UT unless the engineering design specifies it
  • Normal Fluid Service: visual examination of at least 5% of fabrication, plus random RT or UT of at least 5% of circumferential butt and miter groove welds (para. 341.4.1)
  • Category M Fluid Service: a larger random sample than Normal Fluid Service (Chapter VIII, para. M341.4)
  • Severe Cyclic Conditions: 100% RT of circumferential butt, miter groove and fabricated branch welds, or 100% UT where the engineering design specifies it; MT or PT for socket and branch welds not radiographed (para. 341.4.3)
  • High Pressure Fluid Service: examination extent and acceptance criteria set in Chapter IX (para. K341), not by UW-51

Under ASME B31.3, a random sample represents the welds of its designated lot. When a sample reveals a defect, para. 341.3.4 requires progressive examination: two more samples of the same welder’s work; if one of them fails, two further samples for each defective item; if any of those fails, every item the sampling represents is repaired, replaced or fully examined. This statistical sampling approach differs fundamentally from ISO 3834, which specifies examination scope in the quality plan for each weld.

API 1104 — Pipeline Weld RT Criteria

API 1104 (Welding of Pipelines and Related Facilities) governs girth welds in oil and gas transmission pipelines. Section 9 of API 1104 defines RT acceptance criteria that differ from ASME in one critical way: API 1104 uses a density-based area calculation for rounded indications — a concept not present in ISO 10675 or ASME codes.

Elongated Indications (Section 9.3)

For elongated indications (slag, lack of penetration, burn-through) in pipe welds:

  • Crack or lack of fusion: categorically rejectable regardless of length
  • Slag or other elongated imperfections: rejectable if individual length > 50 mm in 300 mm of weld, or if the total combined length exceeds 50 mm in any 300 mm zone, or if any single indication exceeds two-thirds of the weld thickness

Rounded Indications (Section 9.4 — Density Approach)

API 1104 defines acceptance rating for rounded indications (porosity) using a comparison density chart. The interpreter compares the actual indication density on the radiograph against the API 1104 chart for the applicable wall thickness. The chart limits become more restrictive with decreasing wall thickness, reflecting the higher risk that a given porosity density represents in thin-walled pipe relative to thick-wall plate.

In addition to the density criterion:

  • No individual pore may exceed one-quarter of the nominal wall thickness
  • No individual pore may exceed 3.2 mm in diameter
  • For pipe with OD < 60 mm (NPS 2), the applicable acceptance criteria use a smaller reference zone

The API 1104 density chart is reproduced in the code itself and must be used in its original printed form during film interpretation. Photocopied, scanned, or rescaled charts alter the calibration of the density comparison — a common non-conformance finding in pipeline qualification audits.

AWS D1.1 — Structural Steel Radiographic Requirements

AWS D1.1 (Structural Welding Code — Steel) Clause 6 provides RT acceptance criteria for structural steel welds. The code is published by the American Welding Society and is the primary radiographic acceptance reference for structural steel construction in North America. The criteria differ by loading type:

Statically Loaded Structures (Table 6.1)

  • Cracks, lack of fusion, incomplete penetration: categorically rejectable regardless of size
  • Porosity (individual): rejectable if maximum diameter exceeds 3 mm or exceeds one-third of the smaller of base metal thickness or weld thickness
  • Porosity (accumulated): rejectable if the sum of individual pore diameters exceeds 10 mm in any 25 mm of weld length
  • Slag inclusions or elongated indications: rejectable if length > 19 mm for welds > 38 mm thick; acceptance criteria scale with weld thickness for thinner joints
  • Combined indication lengths: the sum of all porosity and slag indication lengths in any 300 mm length of weld may not exceed 19 mm

Cyclically Loaded Structures (Table 6.2)

AWS D1.1 applies stricter criteria for cyclically loaded structures, including full rejection of any individual pore exceeding 2 mm diameter and a tighter accumulated length limit of 10 mm in any 300 mm zone. Incomplete penetration in primary tension members is categorically rejectable regardless of depth.

Standards Comparison Table

CriterionISO 10675-1 Level 1ASME VIII UW-51API 1104 Sec. 9AWS D1.1 Static
CrackReject (all levels)RejectRejectReject
Lack of fusionReject (all levels)RejectRejectReject
Incomplete penetrationReject at L1RejectReject (in most cases)Reject
Slag / elongated: individual0.5t max, 6 mm capt/3 (for t 19–57 mm)50 mm max19 mm (t > 38 mm)
Slag: zone sum2t in 12t zone2t in 150 mm50 mm in 300 mm19 mm in 300 mm
Porosity: individual pore0.25t, max 3 mmPer ASME V App. 4 chartt/4, max 3.2 mm3 mm or t/3
Porosity: zone density1% area in 100 mm×tRounded indication chartDensity comparison chart10 mm sum per 25 mm
Reference zone length100 mm150 mm300 mm300 mm (combined)

Note: table is a general reference. Always consult the current edition of the applicable code — thickness step values, specific alloy exceptions, and service conditions modify the thresholds shown.

Common Failure Modes and Interpretation Errors

Under-reporting of Clustered Porosity

Each code applies a zone limit in addition to an individual pore limit. Interpreters who evaluate each pore in isolation may accept a scatter of small pores that collectively exceed the zone density criterion. Apply the zone limit explicitly to every 100 mm (ISO), 150 mm (ASME), or 300 mm (API/AWS) window across the full weld length.

Misidentifying Indication Type

The acceptance limit for an elongated slag inclusion is typically less restrictive than for a crack — but misidentifying a tight crack as a slag stringer can cause an erroneously passing verdict. Any linear indication with sharp ends or branching geometry should be treated as a potential crack and evaluated against the categorical rejection limit.

Incorrect Weld Thickness Measurement

Many acceptance tables step on weld thickness, not base metal thickness. For a fillet weld or partial-penetration joint, the governing thickness is the throat or the depth of the weld groove, not the base plate. Using the base metal thickness applies a less restrictive limit and can cause acceptance of a rejectable weld.

IQI Sensitivity Failure

If the required Image Quality Indicator (IQI or penetrameter) is not visible on the radiograph, the image does not meet the minimum sensitivity required by the technique standard (ISO 17636, ASME Section V). An acceptance or rejection verdict on a film that fails IQI sensitivity is not valid — the film must be discarded and the joint re-radiographed. This is not an acceptance criteria issue but a technique qualification failure that precedes any acceptance decision.

Failing to Apply the Progressive Examination Rule (ASME B31.3)

Under ASME B31.3 random examination, each defective sample triggers progressive examination of two additional welds of the same kind by the same welder (para. 341.3.4; since the 2022 edition the rule covers only the same welder’s work) and, if one of those fails, two further welds for each defective one. Failure to trigger this progressive examination — accepting the originally failed weld as an isolated event — is a common audit non-conformance.

RT Documentation and ISO 3834 Compliance

EN ISO 3834 requires that every RT examination of a weld covered by the quality plan is supported by a compliant examination record. For EN 1090-2 CE-marked fabrications, these records form part of the technical file that must be available for the duration of the structure’s service life.

Each RT report must include:

Record ItemRequirement
Governing code and editionE.g. ISO 10675-1:2016, Level 1
RT procedure referenceApproved written procedure number and revision
Source type and energyX-ray kV or gamma isotope / activity
IQI type, designation, and placementWire or hole type; which side of the weld
Source-to-film distance (SFD)Documented to validate geometric unsharpness Ug
Film type and processingISO 11699-1 film system class; chemistry temperature
Weld identityDrawing number, joint ID, base material grade, thickness
Indications foundLocation (from datum), type, length, depth estimate if applicable
Acceptance verdictAccept / Reject per code and level
Interpreter qualificationISO 9712 RT Level 2 certificate number and expiry
Date of examinationFor traceability to production lot

Under ISO 9712, the RT interpreter must hold Level 2 certification in radiographic testing for the relevant material sector (welds). Personnel qualification schemes for NDT methods are covered by TWI for common industrial sectors. Level 3 personnel are required to approve the written procedure and may be required by the project specification to countersign interpretation reports for critical welds.

For fabricators transitioning from post-weld RT to inline real-time monitoring, it is important to note that weld process monitoring during welding does not replace post-weld RT in codes that require it — but it reduces reject rates by catching parameter deviations before they create recordable defects. Inline monitoring data can supplement the quality record under ISO 3834 as additional process evidence. See the comparison of inspection methods in our active thermography vs. radiography decision guide for detail on where each method applies.

Frequently Asked Questions

What are the acceptance criteria for radiographic testing of welds?

RT acceptance criteria define the maximum permissible size, length, and area density of discontinuities revealed on a radiographic image. They vary by code: ISO 10675-1 maps three acceptance levels (1, 2, 3) to ISO 5817 quality levels B, C, and D. ASME Section VIII UW-51 rejects any indication whose length exceeds two-thirds of the lesser of weld thickness or 19 mm, among other criteria. API 1104 Section 9 uses absolute length limits combined with a density comparison chart for rounded indications in pipeline welds.

What is ISO 10675-1 and how does it apply to weld RT inspection?

ISO 10675-1 is the European acceptance standard for RT of metallic welds, directly cross-referencing ISO 5817 quality levels B, C, and D as Levels 1, 2, and 3. It is the primary acceptance reference for EN 1090-2 structural fabrication and ISO 3834 certified welding within European and international harmonised standards frameworks.

How do RT acceptance criteria differ between ASME VIII and API 1104?

ASME Section VIII UW-51 applies absolute dimension limits tied to weld thickness in millimetres. API 1104 Section 9 applies both absolute length limits and a density-based comparison chart for rounded indications — a calculation method specific to pipeline girth weld inspection that does not appear in ASME or ISO codes.

What discontinuities can radiographic testing detect in welds?

RT detects volumetric discontinuities: porosity, slag and flux inclusions, tungsten inclusions, lack of penetration, burn-through, and internal cracks. Planar defects perpendicular to the beam — transverse cracks, sidewall lack of fusion at steep bevel angles — can escape detection. PAUT is typically specified alongside RT for fatigue-critical or safety-critical joints.

What are the RT acceptance criteria in AWS D1.1 for structural steel?

AWS D1.1 Clause 6 rejects all cracks, lack of fusion, and incomplete penetration categorically. Porosity and slag inclusions are evaluated against individual pore diameter limits, accumulated zone sums (10 mm per 25 mm zone for static loading), and combined indication limits over any 300 mm of weld.

Does radiographic testing require 100% coverage on all welds?

Required RT coverage depends on code and service conditions. ASME B31.3 Normal Fluid Service requires random RT or UT of at least 5% of circumferential butt and miter groove welds; Category D Fluid Service needs visual examination only; severe cyclic conditions require 100% RT, or UT where the engineering design specifies it. ASME Section VIII mandates 100% RT for specific joint categories and thicknesses. API 1104 requires full coverage of production girth welds. EN 1090-2 execution class and project specifications determine coverage fraction.

What documentation is required for RT weld inspection under ISO 3834?

Each RT report must include the governing code and acceptance level, approved procedure reference, source type and energy, IQI details, source-to-film distance, film type, weld identification (drawing, joint ID, material grade, thickness), all indications found with location and size, acceptance verdict, interpreter’s ISO 9712 Level 2 certificate number, and examination date. Records are retention documents throughout the structure’s design service life.

Can thermal imaging replace RT for weld inspection?

Thermal imaging and RT address different objectives. Inline real-time weld monitoring detects process anomalies during welding — heat input deviation, arc instability — preventing defects from forming. Post-weld active thermography can detect near-surface delaminations. Neither replaces post-weld RT where codes specify it for internal volumetric defect detection. See active thermography vs. radiography for a full method comparison.

Need Inline Weld Quality Monitoring for Your Production Line?

Therness weld monitoring cameras detect heat input deviations and bead geometry anomalies in real time — reducing post-weld reject rates before RT finds them. Contact our technical team to discuss your application.

Contact Therness

Frequently Asked Questions

What are the acceptance criteria for radiographic testing of welds?

RT acceptance criteria define the maximum permissible size, length, and area density of discontinuities revealed on a radiographic image. They vary by code: ISO 10675-1 maps three acceptance levels (1, 2, 3) to ISO 5817 quality levels B, C, and D respectively. ASME Section VIII UW-51 rejects any indication whose length exceeds two-thirds of the lesser of weld thickness or 19 mm, among other criteria. API 1104 Section 9 sets specific limits for elongated and rounded indications in pipeline welds based on length and density within a reference zone.

What is ISO 10675-1 and how does it apply to weld RT inspection?

ISO 10675-1 (Acceptance levels for radiographic testing — Part 1: steel, nickel, titanium and their alloys) is the dedicated RT acceptance standard for fusion-welded joints in metallic materials. It defines three levels: Level 1 (most stringent, maps to ISO 5817 quality level B), Level 2 (maps to ISO 5817 level C), and Level 3 (maps to ISO 5817 level D). Applicable in EN 1090 structural fabrication, ISO 3834 certified welding, and wherever European harmonised standards govern quality. ASME and API codes use their own acceptance tables built into the body of the code, not ISO 10675.

How do RT acceptance criteria differ between ASME VIII and API 1104?

ASME Section VIII Division 1 (UW-51) applies to pressure vessels and evaluates indications against absolute dimensional limits: any crack or zone of incomplete fusion is rejectable; for slag inclusions, the limit is 6 mm for weld thicknesses above 57 mm. API 1104 Section 9 applies to oil and gas pipeline girth welds and uses a combination of absolute length limits and density-based area criteria for rounded indications — a density ratio approach not found in ASME VIII. Both codes apply to the full weld cross-section and require a designated level of RT coverage (typically 100% for API 1104 production welds).

What discontinuities can radiographic testing detect in welds?

RT detects volumetric discontinuities within the weld: porosity (individual pores and clusters), slag and flux inclusions, tungsten inclusions in TIG welds, lack of penetration, burn-through, and internal cracks. RT is most sensitive to defects whose longest dimension is parallel to the X-ray beam. Linear planar defects oriented perpendicular to the beam — such as transverse cracks and lack of sidewall fusion — can be missed, which is why RT is often supplemented by phased-array ultrasonic testing (PAUT) for critical joints.

What are the RT acceptance criteria in AWS D1.1 for structural steel?

AWS D1.1 Clause 6 defines radiographic acceptance criteria for structural steel welds. For statically loaded structures (Table 6.1): any linear indication (crack, lack of fusion, incomplete penetration) is rejectable regardless of length. Porosity, slag, and other rounded or elongated indications are acceptable if: individual length does not exceed 19 mm for welds over 38 mm thick; the sum of indications in any 300 mm of weld does not exceed 19 mm; and no indication in groove welds is greater than one-third of the base metal thickness. Fatigue-loaded structures use stricter criteria from Clause 6.

Does radiographic testing require 100% coverage on all welds?

No. Required RT coverage depends on the applicable code and the joint category or criticality. ASME B31.3 Normal Fluid Service requires random radiography or ultrasonic examination of at least 5% of circumferential butt and miter groove welds (para. 341.4.1); Category D Fluid Service needs visual examination only (para. 341.4.2); severe cyclic conditions require 100% radiography, or 100% ultrasonic examination where the engineering design specifies it (para. 341.4.3). ASME Section VIII mandates 100% RT for Category A (longitudinal) joints in vessels above 38 mm wall and for certain alloys. API 1104 typically requires 100% radiographic or ultrasonic testing on all production girth welds. Under EN 1090-2, the fraction of welds to be examined is specified in the project execution specification and depends on execution class (EXC1–4) and weld category.

What documentation is required for RT weld inspection under ISO 3834?

Under EN ISO 3834, each RT inspection report must include: the applicable code and acceptance level, the approved NDT procedure reference, the film or detector type and IQI used, source-to-film distance and exposure parameters, the identified welds (drawing reference, joint number, material grade, thickness), any indications found with location, size, and disposition, the interpretation verdict against the acceptance criteria, and the Level 2 (or Level 3) interpreter qualification certificate and signature. Records must be retained throughout the design service life of the structure and form part of the CE marking technical file under EN 1090.

Can thermal imaging replace RT for weld inspection?

Thermal imaging and active thermography address different inspection objectives. RT detects internal volumetric defects (porosity, inclusions) in completed welds using ionising radiation. Real-time thermal monitoring during welding detects process anomalies — heat input deviation, arc instability, bead geometry deviation — inline at the point of formation. The two methods are complementary: thermal monitoring prevents defects from forming and reduces the total weld volume requiring post-weld RT. For subsurface defect detection in completed welds, active thermography can detect delaminations and near-surface lack of fusion but does not replace RT for deep internal volumetric defects specified by most construction codes.